Pass a high-pressure gas through a porous plug in a pipe with adiabatic walls. No heat enters from outside. Nothing has been set up to extract work, either. Even so, the temperature of the gas that has passed through the plug changes — and, what is more, it does not necessarily go down. Here we start from the total differential of the enthalpy, define the Joule–Thomson coefficient μ = (∂T/∂p)H, and follow what determines its sign. At the end, we will see that this phenomenon is, just as it stands, the expansion valve of an air conditioner.
First we prepare our tools. Regarding the enthalpy H as a function of p and T, its total differential is
The coefficient on the right is easy to identify. Heat added at constant pressure goes directly into the increase of enthalpy, so
The problem is the coefficient on the left, (∂H/∂p)T. It is hard to measure this directly, so we replace it with a quantity that is easier to measure. This is where the Joule–Thomson coefficient comes in.
The three variables H, p and T are linked by a chain relation (cyclic relation) that always holds mathematically.
Apply this to (H, p, T).
We already know the last two.
Therefore
Putting this back into (1) completes the total differential of the enthalpy.
Place a porous plug in the middle of an adiabatic pipe, push in gas at pressure p1 from the left, and let it emerge on the right at pressure p2 (< p1). Suppose that a volume V1 of gas is pushed in on the left side and a volume V2 is pushed out on the right side.
The work W done on the gas is the work done by the left piston minus the work done on the right piston:
Because the process is adiabatic, Q = 0. By the first law, ΔU = W, that is,
Looking at (3), we can define one more natural quantity: how much the enthalpy changes when the pressure is lowered while the temperature is held constant —
This is called the isothermal Joule–Thomson coefficient. In Section 1 we found (∂H/∂p)T = −μCp, so this is merely a redefinition. Since Cp > 0, μT and μ always have opposite signs.
Trying to measure μ directly would mean “measuring a temperature difference precisely while keeping the system adiabatic,” which is troublesome. In practice, (5) is used the other way around.
Because the temperature can be held constant, we are spared from worrying about the quality of the adiabatic insulation. This is the standard method.
So far we have not used the equation of state at all. From here on we do. Using a thermodynamic relation (a general formula that follows from the Maxwell relations), μ can be written with only the equation of state and Cp. Moreover, only the contents of the square brackets determine the sign, so whether the gas cools or warms is decided by the equation of state alone.
Let us insert the ideal gas, V = nRT/p. Since (∂V/∂T)p = nR/p = V/T, the contents of the square brackets are T·(V/T) − V = 0.
We use the most straightforward model of a real gas.
a is the attraction and b is the size of the molecules (the excluded volume into which molecules cannot enter one another). Substituting into (6) and simplifying (we write w = v − b), we get
For a dilute gas (v ≫ b), this reduces to an easy-to-read form.
When the gas is throttled, it becomes dilute and the average distance between molecules increases.
Which of the two wins is decided by the temperature and density at that point. That is why one cannot flatly say “this gas cools” or “this gas warms”: both occur, depending on conditions.
The set of points where μ = 0, drawn on the (T, p) plane, is the inversion curve. Setting the numerator of (7) to zero gives a simple form for the van der Waals gas.
Combining this with p = p(Tinv, v) and sweeping v, we can draw a closed dome. The two ends at p → 0 are 0.75Tc and 6.75Tc, and the apex is (3Tc, 9pc). Inside the dome is μ > 0 (cooling), and outside it — on the side hotter than the inversion curve and on the side at higher pressure than the inversion curve (above the apex value 9pc, the point is outside whatever the temperature) — is μ < 0 (warming). The side at temperatures below 0.75Tc is also outside the dome, but there the inversion curve is a branch running off to negative pressure (p < 0), and on the low-pressure side, where the gas can exist stably, μ > 0 still holds.
Fig. 1: The sign of μ changes with the conditions. Left: μ versus temperature (one curve per pressure). The temperature at which a curve crosses μ = 0 is the inversion temperature. Right: the inversion curve (the dome), which shows on which side the current point lies. If you select He or H₂, you can see that room temperature is already outside the dome.
| Gas | vdW 2a/Rb | Measured maximum inversion temperature | Ratio |
|---|---|---|---|
| He | 35 K | 45 K | 0.78 |
| H₂ | 223 K | 205 K | 1.09 |
| N₂ | 852 K | 621 K | 1.37 |
| O₂ | 1043 K | 761 K | 1.37 |
| CH₄ | 1287 K | 939 K | 1.37 |
| CO₂ | 2052 K | 1500 K | 1.37 |
Air (N₂ and O₂) has an inversion temperature above 600 K, so if you throttle it straight from room temperature, it cools. The cooled gas precools the incoming gas, which is then throttled again — the apparatus that repeats this to liquefy air is the Linde–Hampson air liquefier. Liquid nitrogen is made this way.
However, H₂ has an inversion temperature of only 205 K and He only 45 K. If you throttle them at room temperature, they warm up instead. Therefore, to liquefy hydrogen, it must first be cooled with liquid nitrogen to around 80 K, bringing it below the inversion temperature, and only then throttled. Helium must be precooled further, with liquid hydrogen or liquid neon — and it is for this reason that low-temperature physics has built up its staircase of “what do we cool with first?”
Inside a household air conditioner is a restriction called the expansion valve, and what happens there is exactly a throttling expansion at constant H. The difference from the experiment in tab ① of the simulator, however, is that the refrigerant enters the region inside the saturation line.
On a p–h diagram, the expansion valve appears as a straight downward line, because h does not change. Look at that vertical line in tab ② of the simulator.
| Component | What it does | In thermodynamic terms |
|---|---|---|
| Compressor | Compresses low-pressure vapor to high pressure | Adiabatic compression (uses electricity) |
| Condenser (outdoor unit) | Rejects heat and returns the vapor to liquid | Constant-pressure heat rejection |
| Expansion valve | Throttles the refrigerant down to low pressure | Isenthalpic change (Joule–Thomson) |
| Evaporator (indoor unit) | Absorbs heat and returns the refrigerant to vapor | Constant-pressure heat absorption |
What is switched between cooling and heating is only the direction in which the refrigerant circulates (the reversing valve), and the roles of the indoor and outdoor units are exchanged. That is why the same machine can do both.
The performance of this device is measured by the coefficient of performance (COP), the heat moved divided by the work put into the compressor. Per 1 kg of refrigerant, let qe be the heat received in the evaporator, qk the heat rejected in the condenser, and w the work put into the compressor. Then the COP for cooling is qe/w and the COP for heating is qk/w. In steady operation qk = qe + w, so for the same cycle the COP for heating is greater than the COP for cooling by exactly 1.
| Question | Answer |
|---|---|
| Why does H not change when a gas is throttled? | Because the process is adiabatic, Q = 0, and the difference between the work of pushing in and the work of pushing out becomes ΔU (Eq. 4) |
| What is μ? | The temperature change when the pressure is changed at constant H, (∂T/∂p)H. From the chain relation, (∂H/∂p)T = −μCp (Eq. 3) |
| Why does it not occur in an ideal gas? | Because T(∂V/∂T)p = V holds exactly, μ = 0 |
| What decides whether the gas cools or warms? | Which wins: the attraction 2a/RT or the size b. The boundary is the inversion curve (Eqs. 8, 9) |
| Why does hydrogen warm up at room temperature? | Its inversion temperature is only 205 K, so room temperature is already outside the dome |
| Where is it in an air conditioner? | The expansion valve. It is the straight downward line on the p–h diagram |
The van der Waals constants a and b are tabulated values fitted to the critical point, and Cp is the ideal-gas part obtained from the partition function with a correction for the real gas added. The measured inversion temperatures are standard literature values from cryogenic engineering. Related pages: Derivation of the ideal gas, Derivation of the Carnot cycle, The simulator.